2/17/2024 0 Comments 100 amp service cable![]() ![]() PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. The jacket protects the inner components of the cable from potentially damaging external forces. The cable jacket used in its design is Polyvinyl Chloride (PVC). For color code, see table B in the technical section. The conductors are cabled together with a bare aluminum ground and covered with a reinforced binder tape. Insulation:Īluminum SER cable has a type XHHW-2 cross linked polyethylene (XLP) insulation. The conductor is the electrode in the cable and is responsible for transmitting electric current. Standards:Īmpacities based on National Electric Code, 2005 edition, section 310-15Ħ0☌ when terminated to equipment for circuits rated 100 Amps or less or marked for 14 gauge through 1 gauge conductorsħ0☌ when terminated to equipment for circuits rated over 100 Amps or marked for conductors larger than 1 gaugeįor dwelling units, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single phase service conductors that supply the total loadĪluminum type R cable has compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801. Also Known As:ġ-1-1-3 type r cable, 1-1-1-3 service entrance cable, 1-1-1-3 ser cable, 1-1-1-3 aluminum ser cable, 1-1-1-3 aluminum service entrance cable, 1-1-1-3 electrical entrance cable. In addition, SER cables can operate at 70 ° C when the electrical cable is terminated to equipment in circuits rated over 100 Amps or when marked for conductors larger than 1 gauge. However, type R cables can operate at 60 ° C when terminated to equipment for circuits rated at 100 Amps or less or if it is marked for 14 gauge through 1 gauge conductors. Aluminum service entrance cables are designed for use in adverse weather conditions, with operating temperatures being 90 ° C in both wet and dry locations. The voltage rating for this electrical cable is 600 volts. Product Information Specification 1-1-1-3 ALUMINUM SER CABLEĪllowable Ampacity fo r 1-1-1-3 ALUMINUM SER CABLE at 60☌: 85 AmpsĪllowable Ampacity fo r 1-1-1-3 ALUMINUM SER CABLE at 75☌: 100 AmpsĪllowable Ampacity fo r 1-1-1-3 ALUMINUM SER CABLE at 90☌: 115 Amps Applications:Īluminum service entrance cable is mainly used in branch circuits and panel feeders. Professional headsets and intercom solutions (1). ![]() Portable testing and measuring equipment (13).Multimedia hub, adapter, cables & port (4).
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |